Lab&field calibration scheme |
|
|
|
|
Laboratory Bench-top Product Scheme
HX7620C + HX7610TA + HX600 + HXP + V2008
Product Description
The scheme is designed to meet the need of calibrating pressure in the lab. The special pressure pumps adopt the fine stainless steel technology, and they are compact, labor-saving, light, easily carrying. Besides, the pneumatic, and the hydraulic comparator test pumps can cover pressure range (-0.98~720)bar. Three intelligent pressure calibrators allow checking minute-pressure / low-pressure / medium-pressure gauges, pressure transducers, pressure switch and so on.
Characteristics
- Platen, compact, open, clear, easy-operating.
- Fine stainless steel and hermetic technology in the military industry.
- Whole pressure range covering: vacuum,pneumatic and hydraulic pressure.
- Automatic data record and form making, amending calculating errors, checking and storing data, which decreases the possibility of errors by human and improve efficiency.
- As per users’ demands to tune the solution.
- Transparent oil cup, double filters, fixed rotary slide structure; Save space.
- It could calibrate two instruments at the same time.

Type |
Technical Specification |
Qty |
Remark |
HX7610TA |
- Pressure range: (0~720) bar
- Stability:0.05%F.S
- Output Interface: M20×1.5
- Working media: Transformer oil
|
1Pcs |
|
HX7620C |
- Pressure range: (-0.98~60) bar
- Stability:0.02%F.S
- Output Interface: M20×1.5
- Working media: Air
|
1Pcs |
|
HX7400A |
- Pressure range: (0~720) bar
- Stability:0.05%F.S
- Output Interface: M20×1.5
- Working media: Distilled water
|
1Pcs |
Optional
|
HX600 |
- Pressure measurement:(-1~2500)bar
Accuracy:0.05%F.S
- Current measurement:(0~25)mA,
Accuracy:±(0.02%RD+0.005%F.S)
- Voltage measurement:(0~25)V,
Accuracy:±(0.02%RD+0.005%F.S)
- Switching Value measurement: to measure the on-off state
- DC output:DC24V (≤30mA), Accuracy:±1%F.S
- Communication:RS232
- Module interface:M20×1.5
|
1Pcs |
|
HXPDM |
- Range:(-1~0)bar(0~700)bar
- Accuracy:±0.05%F.S
|
8Pcs |
According to the customers demand |
V2008 |
- Operation Interface: Windows 2000/XP
- Operating easily: the computer collects the data,
- Calculate, save, generate the calibrating results, and print out the certification or reports automatically; The data could be saved at least for three calibrating cycles.
- Site Statistics: According to the data in the data base, manufacturer or instrument batch No. to count the records;
- Query Function: The history data could be check according to the instrument type, serial No., user, calibrating time etc.
- Records and Certification Format: The Format could be made according to the users’ requirement.
- Free upgrade.
|
1Pcs |
|
Computer |
Lenovo Computer:Memory:2G,Hard Disk:≥250G |
1Pcs |
|
Printer |
HP1007 |
1Pcs |
|
Fittings |
HX3002 pressure Joints and Maintenance tools |
1Pcs |
|
|
|
|